Booking today · Miami, Los Angeles, Houston, New York and San Diego · three-hour arrival windows Independent commercial equipment repair · Every maker on this site Mon–Fri 7:00 AM - 8:00 PM · Sat 8:00 AM - 6:00 PM
(844) 393-0816 Schedule a Visit
Model series · Manitowoc · Ice machines

Manitowoc S-Model Ice Machines

Current and older. 84 model numbers in this series.

01Model numbers

Model numbers in this series

Find yours on the data plate. Letters after the base number usually mark the voltage, finish or door and do not change the repair.

  • SD0302A
  • SY0304A
  • SD0322A
  • SY0324A
  • SR0420A
  • SD0422A
  • SY0424A
  • SD0452A
  • SY0454A
  • SR0500A
  • SD0502A
  • SY0504A
  • SD0602A
  • SY0604A
  • SR0850A
  • SD0852A
  • SY0854A
  • SR1000A
  • SD1002A
  • SY1004A
  • SD1202A
  • SY1204A
  • SD1402A
  • SY1404A
  • SR1600A
  • SD1602A
  • SY1604A
  • SR1800A
  • SD1802A
  • SY1804A
  • SD0303W
  • SY0305W
  • SD0323W
  • SY0325W
  • SR0421W
  • SD0423W
  • SY0425W
  • SD0453W
  • SY0455W
  • SR0501W
  • SD0503W
  • SY0505W
  • SD0603W
  • SY0605W
  • SR0851W
  • SD0853W
  • SY0855W
  • SR1001W
  • SD1003W
  • SY1005W
  • SD1203W
  • SY1205W
  • SD1403W
  • SY1405W
  • SR1601W
  • SD1603W
  • SY1605W
  • SR1801W
  • SD1803W
  • SY1805W
  • SD3303W
  • SD3303WHP
  • SY3305W
  • SY3305WHP
  • SDT3000W
  • SYT3000W
  • SD0592N
  • SY0594N
  • SD0692N
  • SY0694N
  • SR0890N
  • SD0892N
  • SY0894N
  • SR1090N
  • SD1092N
  • SY1094N
  • SD1492N
  • SY1494N
  • SR1690N
  • SD1692N
  • SY1694N
  • SR1890N
  • SD1892N
  • SY1894N

Repairs this series usually needs

  1. Safety Limit 1 long freeze
  2. Safety Limit 2 long harvest
  3. Safety Limit 3 low pressure on quad evaporator models
  4. Scale on the plate and probe
  5. Condenser heat and dirt

The S-model line includes SD, SY and SR cubers such as the SD0302A, SY0604A, SR1000A, SD1402A and SY1804A, plus the SDT3000 and SYT3000. A number ending in 3 marks a three-phase unit. A single light on the board flashes once, twice or three times to say which safety limit stopped the machine.

One flash means a long freeze, two flashes mean a long harvest, and three flashes mean the low refrigerant pressure control opened on a quad evaporator model. The machine restarts after the toggle is moved off and back to ice, but the cause stays until it is fixed.

We check water, scale, probes and airflow first, then the harvest valve and the refrigerant side. Older units get honest repair-or-replace advice.

About this series

  • Self-contained air- and water-cooled and remote cubers
  • Single and quad evaporator versions
  • Harvest and safety limit light that flashes one, two or three times
  • Model numbers ending in 3 are three-phase units
  • Includes SD, SY and SR models and the SDT and SYT 3000 versions
FAQManitowoc S-Model Ice Machines questions
How do I tell which limit tripped?

Move the toggle switch to OFF and back to ICE, then watch the harvest light. One or two flashes identify the limit. Three flashes appear on quad evaporator models.

What is a quad evaporator?

It is a machine with four evaporator plates, used on the larger S-model cubers. They have an extra low pressure safety, which is why three flashes only occur there.

Is the S-model an older line?

It is both current and older, depending on the model. Many are in service for years. We repair them and tell you when the cost is not sensible.

Book a visit

Book repair for your Manitowoc S-Model Ice Machines

Tell us the maker, the model number from the data plate and what the unit is doing. We confirm a three-hour arrival window and give you a written price before any work starts.

☎ Call our office ▤ Schedule a Visit