Common Frymaster problems we fix

In plain words, the way kitchen and laundry staff describe them when they call.

01

Fryer will not heat

02

HEATING FAILURE message on the display

03

Temperature probe failure message

04

Slow oil recovery or recovery alarm

05

Filter pump not filling the vat

06

Oil leaking at the drain valve

07

Pilot will not stay lit

Frymaster Families and Controls

Frymaster builds fryers in several families, and we work on current and older ones. On the electric side that means RE14 and RE17 open-vat fryers, FilterQuick batteries with built-in filtration, and OCF30 models. The gas lines include H55, HD and LHD65 fryers, 1814 oil-conserving fryers, and millivolt MJ40 and ESG35T units that need no electrical connection. Older MJ35, MJ45, H55-2, HD50G and BIGLA30 filter batteries still work hard in many kitchens, and we repair those as well.

Controls differ as much as the fryers do: Digital Timer, CM3.5, Thermatron, the 3000 controller, FQ4000 EasyTouch and plain millivolt thermostats. A fryer line collects grease on every surface, and in a hot, humid kitchen that load shortens the life of probes, connectors and filter parts.

Our First Checks

When a fryer will not heat, we start with the gas valve, high limit and contactor, then the temperature probe. A 3000 controller that reports a heating failure, a probe failure or a recovery alarm points us to the same short list. If the filter pump will not fill the vat, or a drain or return valve does not confirm its position, we look at the filter pad, the O-rings, the pump and the valve linkage. Oil leaks usually trace back to the drain valve or the filter pan seals.

On an older fryer we say plainly when a repair no longer makes sense. We confirm the model and controller type before the visit so the right parts arrive with us, give you a written price before work starts, and back our work with a 30-day workmanship warranty.

→Error codes

Frymaster codes and alarms

What the display or the blinking light means, what is safe to check, and when to stop and call us.

E03 ERROR TEMP PROBE FAILUREFrymaster 3000 Fryer Error Code E03: Temp Probe FailureE04 HI 2 BADFrymaster 3000 Fryer Error Code E04: HI 2 BadE05 HOT HI 1 (HOT-HI-1)Frymaster 3000 Fryer Error Code E05: Hot HI 1E06 HEATING FAILUREFrymaster 3000 Fryer Error Code E06: Heating FailureE08 ERROR ATO BOARDFrymaster 3000 Fryer Error Code E08: Error ATO BoardE17 ERROR ATO PROBEFrymaster 3000 Fryer Error Code E17: Error ATO ProbeE20 INVALID CODE LOCATIONFrymaster 3000 Fryer Error Code E20: Invalid Code LocationE21 FILTER PAD PROCEDURE ERROR (Change Filter Pad)Frymaster 3000 Fryer Error Code E21: Change Filter PaperE22 OIL IN PAN ERRORFrymaster 3000 Fryer Error Code E22: Oil in Pan ErrorE25 RECOVERY FAULTFrymaster 3000 Fryer Error Code E25: Recovery FaultLOW TEMP ALARMFrymaster 3000 Fryer Error Code E27: Low Temp AlarmE28Frymaster 3000 Fryer Error Code E28: High Temp AlarmREMOVE DISCARD (Right)Frymaster M3000 Fryer Error Code E01: Remove Discard (Right)REMOVE DISCARD (Left)Frymaster M3000 Fryer Error Code E02: Remove Discard (Left)ERROR MIB SOFTWAREFrymaster M3000 Fryer Error Code E07: Error MIB SoftwareERROR PUMP NOT FILLINGFrymaster M3000 Fryer Error Code E09: Pump Not FillingERROR DRAIN VALVE NOT OPENFrymaster M3000 Fryer Error Code E10: Drain Valve Not OpenERROR DRAIN VALVE NOT CLOSEDFrymaster M3000 Fryer Error Code E11: Drain Valve Not ClosedERROR RETURN VALVE NOT OPENFrymaster M3000 Fryer Error Code E12: Return Valve Not OpenERROR RETURN VALVE NOT CLOSEDFrymaster M3000 Fryer Error Code E13: Return Valve Not ClosedERROR AIF BOARDFrymaster M3000 Fryer Error Code E14: Error AIF BoardERROR MIB BOARDFrymaster M3000 Fryer Error Code E15: Error MIB BoardERROR AIF PROBEFrymaster M3000 Fryer Error Code E16: Error AIF ProbeM3000 CAN TX FULLFrymaster M3000 Fryer Error Code E19: CAN TX Full

All 32 Frymaster fryers codes

FAQFrymaster questions
Do you repair older Frymaster fryers like the MJ45 and BIGLA30?

Yes. We service MJ35, MJ45, H55-2 and BIGLA30 units along with current models. Tell us the model and the controller on the front, and we plan the parts before the visit. If a repair is not worth it, we say so.

What does E05 HOT HI 1 mean on a Frymaster 3000 controller?

It means the high-limit temperature went above 410 degrees F. Shut the fryer down and call us. Hot oil over temperature is not something to keep cooking through, and we test the high-limit circuit and probe.

Why will my millivolt Frymaster fryer not light?

MJ40 and ESG35T fryers have no electrical connection, so the pilot and gas valve do all the work. Make sure the gas is on. If you smell gas, leave the building and call the gas utility from outside. Otherwise call us.

Book a visit

Book Frymaster repair in Miami, Los Angeles, Houston, New York and San Diego

Tell us the maker, the model number from the data plate and what the unit is doing. We confirm a three-hour arrival window and give you a written price before any work starts.

☎ Call our office ▤ Schedule a Visit